Share this:

CHEMISTRY FORM ONE NOTES

 

Introduction to chemistry

Chemistry is a branch of Science. Science is basically the study of living and non-living things. The branch of science that study living things is called Biology. The branch of science that study non-living things is called Physical Science. Physical Science is made up of:

  1. Physics- the study of matter in relation to energy
  2. Chemistry- the study of the composition of matter.

Chemistry is thus defined as the branch of science that deals with the structure composition, properties and behavior of matter.

Basic Chemistry involves studying:

  1. States/phases of matter

Matter is anything that has weight/mass and occupies space/volume. Naturally, there are basically three states of matter.

 (i) Solid-e.g. soil, sand, copper metal, bucket, ice.

 (ii)Liquid- e.g. water, Petrol, ethanol/alcohol, Mercury (liquid metal).

 (iii) gas- e.g. Oxygen, Nitrogen ,Water vapour.

A solid is made up of particles which are very closely packed. It thus has a definite/fixed shape and fixed/definite volume /occupies definite space. It has a very high density.

A liquid is made up of particles which have some degree of freedom. It thus has no definite/fixed shape. It takes the shape of the container it is put. A liquid has fixed/definite volume/occupies definite space.

A gas is made up of particles free from each other. It thus has no definite/fixed shape. It takes the shape of the container it is put. It has no fixed/definite volume/occupies every space in a container.

(b) Separation of mixture

A mixture is a combination of two or more substances that can be separated by physical means. Simple methods of separating mixtures at basic chemistry level include:

i) Sorting/picking-this involve physically picking one pure substance from a mixture with another/other. e. g. sorting maize from maize beans mixture.

ii) Decantation-this involve pouring out a liquid from a solid that has settled /sinking solid in it. e. g. Decanting water forms sand.

ecolebooks.com

iii)Filtration-this involves sieving /passing particles of a mixture through a filter containing small holes that allow smaller particle to pass through but do not allow bigger particle to pass through.

iv) Skimming-this involve scooping floating particles. E.g. cream from milk

(c) Metals and non-metals

Metals are shiny, ductile(able to form wires), malleable(able to form sheet) and coil without breaking. E.g. Iron, gold, silver, copper. Mercury is the only liquid metal known.

Non-metals are dull, not ductile (do not form wires), not malleable (do not form sheet) and break on coiling/brittle. E.g. Charcoal, Sulphur, pla-stics.

(d) Conductors and non-conductors

A conductor is a solid that allow electric current to pass through. A non-conductor is a solid that do not allow electric current to pass through.

All metals conduct electricity. All non-metals do not conduct electricity except carbon graphite.

(e) Drugs

A drug is a natural or synthetic/man-made substance that when taken changes/alter the body functioning. A natural or synthetic/man-made substance that when taken changes/alter the abnormal body functioning to normal is called medicine. Medicines are thus drugs intended to correct abnormal body functions. . Medicines should therefore be taken on prescription and dosage.

A prescription is a medical instruction to a patient/sick on the correct type of medicine to take and period/time between one intake to the other.

A dosage is the correct quantity of drug required to alter the abnormal body function back to normal. This is called treatment. It is the professional work of qualified doctors/pharmacists to administer correct prescription and dosage of drugs/medicine to the sick. Prescription and dosage of drugs/medicine to the sick use medical language.

Example

 (i) 2 x 4 means “2” tablets for solid drugs/spoonfuls for liquid drugs taken “4” times for a duration of one day/24 hours and then repeated and continued until all the drug given is finished.

 (ii) 1 x 2 means “1” tablets for solid drugs/spoonfuls for liquid drugs taken “2” times for a duration of one day/24 hours and then repeated and continued until all the drug given is finished.

Some drugs need minimal prescription and thus are available without pharmacist/ doctor’s prescription. They are called Over The Counter (OTC) drugs. OTC drugs used to treat mild headaches, stomach upsets, common cold include:

 (i) Painkillers

 (ii) Anti-acids

 (iii) cold/flu drugs.

All medicine requires correct intake dosage. When a prescription dosage is not followed, this is called drug misuse/abuse. Some drugs are used for other purposes other than that intended. This is called drug abuse.


Drug abuse is when a drug is intentionally used to alter the normal functioning of the body. The intentional abnormal function of the drug is to make the victim have false feeling of well being. The victim lack both mental and physical coordination.

Some drugs that induce a false feeling of well being are illegal. They include heroin, cocaine, bhang, Mandrax and morphine.

Some abused drugs which are not illegal include: Miraa, alcohol, tobacco, sleeping pills.

The role of chemistry in society

(a) Chemistry is used in the following:

(i) Washing/cleaning with soap:

Washing/cleaning is a chemical process that involves interaction of water, soap and dirt so as to remove the dirt from a garment.

(ii) Understanding chemicals of life

Living thing grow, respire and feed. The formation and growth of cells involve chemical processes in living things using carbohydrates, proteins and vitamins.

(iii) Baking:

Adding baking powder to dough and then heating in an oven involves interactions that require understanding of chemistry.

(iv) Medicine:

Discovery, test, prescription and dosage of drugs to be used for medicinal purposes require advanced understanding of chemistry

(v) Fractional distillation of crude oil:

Crude oil is fractional distilled to useful portions like petrol, diesel, kerosene by applying chemistry.

(vi) Manufacture of synthetic compounds/substances

Large amounts of plastics, glass, fertilizers, insecticides, soaps, cements, are manufactured worldwide. Advanced understanding of the chemical processes involved is a requirement.

(vii) Diagnosis/test for abnormal body functions.

If the body is not functioning normally, it is said to be sick/ill. Laboratory test are done to diagnose the illness/sickness.


(b) The following career fields require Chemistry as one of subject areas of advanced/specialized study:

(i) Chemical engineering/chemical engineer

(ii) Veterinary medicine/Veterinary doctor

(iii) Medicine/Medical doctor/pharmacist/nurse

(iv) Beauty/Beautician

(v) Teaching/Chemistry teacher.

The School Chemistry Laboratory

Chemistry is studied mainly in a science room called a school chemistry laboratory. The room is better ventilated than normal classroom. It has electricity, gas and water taps. A school chemistry laboratory has a qualified professional whose called Laboratory technician/assistant.

All students user in a school chemistry laboratory must consult the Laboratory technician/assistant for all their laboratory work. A school chemistry laboratory has chemicals and apparatus.

A chemical is a substance whose composition is known. All chemical are thus labeled as they are. This is because whereas physically a substance may appear similar, chemically they may be different.

All Chemicals which are not labeled should never be used. Some chemicals are toxic/poisonous, explosive, corrosive, caustic, irritants, flammable, oxidizing, carcinogenic, or radioactive.

Care should always be taken when handling any chemical which have any of the above characteristic properties.

Common school chemistry laboratory chemicals include:

(i) Distilled water

(ii) Concentrated mineral acid which are very corrosive (on contact with skin they cause painful open wounds)

(iii) Concentrated alkali/bases which are caustic (on contact with skin they cause painful blisters)

(iv) Very many types of salts

The following safety guideline rules should be followed by chemistry laboratory users:

(i) Enter the laboratory with permission in an orderly manner without rushing/pushing/scrabbling.

(ii) Do not try unauthorized experiments. They may produce flammable, explosive or toxic substances that affect your health.

(iii) Do not taste any chemical in the laboratory. They may be poisonous.

(iv) Waft gas fumes to your nose with your palm. Do not inhale/smell gases directly. They may be highly poisonous/toxic.

(v) Boil substances with mouth of the test tube facing away from others and yourself. Boiling liquids spurt out portions of the hot liquid. Products of heating solids may be a highly poisonous/toxic gas.

(vi) Wash with lots of water any skin contact with chemicals immediately. Report immediately to teacher/laboratory technician any irritation, cut, burn, bruise or feelings arising from laboratory work.

(vii) Read and follow safety instruction. All experiments that evolve/produce poisonous gases should be done in the open or in a fume chamber.

(viii )Clean your laboratory work station after use. Wash your hand before leaving the chemistry laboratory.

(ix) In case of fire, remain calm, switch of the source of fuel-gas tap. Leave the laboratory through the emergency door. Use fire extinguishers near the chemistry laboratory to put of medium fires. Leave strong fires wholly to professional fire fighters.

(x) Do not carry unauthorized item from a chemistry laboratory.

An apparator /apparatus are scientific tools/equipment used in performing scientific experiments. The conventional apparator used in performing scientific experiments is called standard apparator/apparatus. If the conventional standard apparator/apparatus is not available, an improvised apparator/apparatus may be used in performing scientific experiments. An improvised apparator/apparatus is one used in performing a scientific experiment for a standard apparator/apparatus. Most standard apparatus in a school chemistry laboratory are made of glass because:

(i)Glass is transparent and thus reactions /interactions inside are clearly visible from outside

(ii) Glass is comparatively cheaper which reduces cost of equipping the school chemistry laboratory

(iii) Glass is comparatively easy to clean/wash after use.
(iv) Glass is comparatively unreactive to many chemicals.

Apparatus are designed for the purpose they are intended in a school chemistry laboratory:

  1. Apparatus for measuring volume

1. Measuring cylinder

Measuring cylinders are apparatus used to measure volume of liquid/ solutions. They are calibrated/ graduated to measure any volume required to the maximum. Measuring cylinders are named according to the maximum calibrated/graduated volume e.g.

“10ml” measuring cylinder is can hold maximum calibrated/graduated volume of “10mililitres” /”10 cubic centimetres”

“50ml” measuring cylinder is can hold maximum calibrated/graduated volume of “50mililitres” /”50 cubic centimetres”

“250ml” measuring cylinder is can hold maximum calibrated/graduated volume of “250mililitres” /”250 cubic centimetres”

“1000ml” measuring cylinder is can hold maximum calibrated/graduated volume of “1000mililitres” /”1000 cubic centimetres”

2. Burette

Burette is a long and narrow/thin apparatus used to measure small accurate and exact volumes of a liquid solution. It must be clamped first on a stand before being used. It has a tap to run out the required amount out. They are calibrated/ graduated to run out small volume required to the maximum 50ml/50cm3.

The maximum 50ml/50cm3 calibration/ graduation reading is at the bottom .This ensure the amount run out from a tap below can be determined directly from burette reading before and after during volumetric analysis.

Burettes are expensive and care should be taken when using them.

3. (i) Pipette

Pipette is a long and narrow/thin apparatus that widens at the middle used to measure and transfer small very accurate/exact volumes of a liquid solution.

It is open on either ends.

The maximum 25ml/25cm3 calibration/ graduation mark is a visible ring on one thin end.

To fill a pipette to this mark, the user must suck up a liquid solution upto a level above the mark then adjust to the mark using a finger.

This requires practice.

(ii) Pipette filler

Pipette filler is used to suck in a liquid solution into a pipette instead of using the mouth. It has a suck, adjust and eject button for ensuring the exact volume is attained. This requires practice.

4. Volumetric flask.

A volumetric flask is thin /narrow but widens at the base/bottom. It is used to measure very accurate/exact volumes of a liquid solution.

The maximum calibration / graduation mark is a visible ring.

Volumetric flasks are named according to the maximum calibrated/graduated volume e.g.

“250ml” volumetric flask has a calibrated/graduated mark at exact volume of “250mililitres” /”250centimetres”

“1l” volumetric flask has a calibrated/graduated mark at exact volume of “one litre” /”1000 cubic centimeters”

“2l” volumetric flask has a calibrated/graduated mark at exact volume of “two litres” /”2000 cubic centimeters”

5. Dropper/teat pipette

A dropper/teat pipette is a long thin/narrow glass/rubber apparatus that has a flexible rubber head.

A dropper/teat pipette is used to measure very small amount/ drops of liquid solution by pressing the flexible rubber head. The numbers of drops needed are counted by pressing the rubber gently at a time

(b)Apparatus for measuring mass

1. Beam balance

A beam balance has a pan where a substance of unknown mass is placed. The scales on the opposite end are adjusted to “balance” with the mass of the unknown substance. The mass from a beam balance is in grams.

2. Electronic/electric balance.

An electronic/electric balance has a pan where a substance of unknown mass is placed. The mass of the unknown substance in grams is available immediately on the screen.

 

(c)Apparatus for measuring temperature

A thermometer has alcohol or mercury trapped in a bulb with a thin enclosed outlet for the alcohol/mercury in the bulb.

If temperature rises in the bulb, the alcohol /mercury expand along the thin narrow enclosed outlet.

The higher the temperature, the more the expansion

Outside, a calibration /graduation correspond to this expansion and thus changes in temperature.

A thermometer therefore determines the temperature when the bulb is fully dipped in to the substance being tested. To determine the temperature of solid is thus very difficult.

(d)Apparatus for measuring time

The stop watch/clock is the standard apparatus for measuring time. Time is measured using hours, minutes and second.

Common school stop watch/clock has start, stop and reset button for determining time for a chemical reaction. This requires practice.

(e) Apparatus for scooping

1. Spatula

A spatula is used to scoop solids which do not require accurate measurement. Both ends of the spatula can be used at a time.

A solid scooped to the brim is “one spatula end full” A solid scooped to half
brim is “half spatula end full”.

2. Deflagrating spoon

A deflagrating spoon is used to scoop solids which do not require accurate measurement mainly for heating. Unlike a spatula, a deflagrating spoon is longer.


(f) Apparatus for putting liquids/solid for heating.

1. Test tube.

A test tube is a narrow/thin glass apparatus open on one side. The end of the opening is commonly called the “the mouth of the test tube”.

2. Boiling/ignition tube.

A boiling/ignition tube is a wide glass apparatus than a test tube open on one side. The end of the opening is commonly called the “the mouth of the boiling/ignition tube”.

3. Beaker.

Beaker is a wide calibrated/graduated lipped glass/plastic apparatus used for transferring liquid solution which do not normally require very accurate measurements

Beakers are named according to the maximum calibrated/graduated volume they can hold e.g.

“250ml” beaker has a maximum calibrated/graduated volume of “250mililitres” /”250 cubic centimeters”

“1l” beaker has a maximum calibrated/graduated volume of “one litre” /”1000 cubic centimeters”

“5 l” beaker has a maximum calibrated/graduated volume of “two litres” /”2000 cubic centimeters”

4. Conical flask.

A conical flask is a moderately narrow glass apparatus with a wide base and no calibration/graduation. Conical flasks thus carry/hold exact volumes of liquids that have been measured using other apparatus. It can also be put some solids. The narrow mouth ensures no spillage.

Conical flasks are named according to the maximum volume they can hold e.g. “250ml” Conical flasks hold a maximum volume of “250mililitres” /”250 cubic centimeters”

“500ml” Conical flasks hold a maximum volume of “500ml” /”1000 cubic centimeters”

5. Round bottomed flask

A round bottomed flask is a moderately narrow glass apparatus with a wide round base and no calibration/graduation. Round bottomed flask thus carry/hold exact volumes of liquids that have been measured using other apparatus. The narrow/thin mouth prevents spillage. The flask can also hold (weighed) solids. A round bottomed flask must be held/ clamped when in use because of its wide narrow base.

6. Flat bottomed flask

A flat bottomed flask is a moderately narrow glass apparatus with a wide round base with a small flat bottom. It has no calibration/graduation.

Flat bottomed flasks thus carry/hold exact volumes of liquids that have been measured using other apparatus. The narrow/thin mouth prevents spirage. They can also hold (weighed) solids. A flat bottomed flask must be held/ clamped when in use because it’s flat narrow base is not stable.

(g) Apparatus for holding unstable apparatus (during heating).

1. Tripod stand

A tripod stand is a three legged metallic apparatus which unstable apparatus are placed on (during heating).Beakers. Conical flasks, round bottomed flask and flat bottomed flasks are placed on top of tripod stand (during heating).

2. Wire gauze/mesh

Wire gauze/mesh is a metallic/iron plate of wires crossings. It is placed on top of a tripod stand:

 (i) Ensure even distribution of heat to prevent cracking glass apparatus

 (ii) Hold smaller apparatus that cannot reach the edges of tripod stand

3 Clamp stand

A clamp stand is a metallic apparatus which tightly hold apparatus at their “neck” firmly.

A clamp stand has a wide metallic base that ensures maximum stability. The height and position of clamping is variable. This require practice

4. Test tube holder

A test tube holder is a hand held metallic apparatus which tightly hold test/boiling/ignition tube at their “neck” firmly on the other end.

Some test tube holders have wooden handle that prevent heat conduction to the hand during heating.  

5. Pair of tong.

A pair of tong is a scissor-like hand held metallic apparatus which tightly hold firmly a small solid sample on the other end.

6. Gas jar

A gas jar is a long wide glass apparatus with a wide base.

It is open on one end. It is used to collect/put gases.

This requires practice.

(h) Apparatus for holding/directing liquid solutions/funnels (to avoid spillage).

1. Filter funnel

A filter funnel is a wide mouthed (mainly plastic) apparatus that narrow drastically at the bottom to a long extension.

When the long extension is placed on top of another apparatus, a liquid solution can safely be directed through the wide mouth of the filter funnel into the apparatus without spirage.

Filter funnel is also used to place a filter paper during filtration.

2. Thistle funnel

A thistle funnel is a wide mouthed glass apparatus that narrow drastically at the bottom to a very long extension.

The long extension is usually drilled through a stopper/cork.

A liquid solution can thus be directed into a stoppered container without spillage

3. Dropping funnel

A dropping funnel is a wide mouthed glass apparatus with a tap that narrow drastically at the bottom to a very long extension.

The long extension is usually drilled through a stopper/cork.

A liquid solution can thus be directed into a stoppered container without spillage at the rate determined by adjusting the tap.

4. Separating funnel

A separating funnel is a wide mouthed glass apparatus with a tap at the bottom narrow extension.

A liquid solution can thus be directed into a separating funnel without spillage. It can also safely be removed from the funnel by opening the tap.

It is used to separate two or more liquid solution mixtures that form layers/immiscible. This requires practice.

 


(h) Apparatus for heating/Burners

1. Candle, spirit burner, kerosene stove, charcoal burner/jiko are some apparatus that can be used for heating.

Any flammable fuel when put in a container and ignited can produce some heat.

2. Bunsen burner

The Bunsen burner is the standard apparatus for heating in a Chemistry school laboratory.

It was discovered by the German Scientist Robert Wilhelm Bunsen in1854.

(a)Diagram of a Bunsen burner

 

Image From EcoleBooks.com

 

A Bunsen burner uses butane/laboratory gas as the fuel. The butane/laboratory gas is highly flammable and thus usually stored safely in a secure chamber outside Chemistry school laboratory. It is tapped and distributed into the laboratory through gas pipes.

The gas pipes end at the gas tap on a chemistry laboratory bench .If opened the gas tap releases butane/laboratory gas. Butane/laboratory gas has a characteristic odor/smell that alerts leakages/open gas tap.

The Bunsen burner is fixed to the gas tap using a strong rubber tube.

The Bunsen burner is made up of the following parts:

(i) Base plate –to ensure the burner can stand on its own

(ii)Jet-a hole through which laboratory gas enters the burner

(iii)Collar/sleeve-adjustable circular metal attached to the main chimney/burell with a side hole/entry. It controls the amount of air entering used during burning.

(iv)Air hole- a hole/entry formed when the collar side hole is in line with chimney side hole. If the collar side hole is not in line with chimney side hole, the air hole is said to be “closed” If the collar side hole is in line with chimney side hole, the air hole is said to be “open”

(v)Chimney- tall round metallic rod attached to the base plate.

(b)Procedure for lighting/igniting a Bunsen burner

1. Adjust the collar to ensure the air holes are closed.

2. Connect the burner to the gas tap using a rubber tubing. Ensure the rubber tubing has no side leaks.

3. Turn on the gas tap.

4. Ignite the top of the chimney using a lighted match stick/gas lighter/wooden splint.

5. Do not delay excessively procedure (iv) from (iii) to prevent highly flammable laboratory gas from escaping/leaking.

(c)Bunsen burner flames

A Bunsen burner produces two types of flames depending on the amount of air entering through the air holes.

If the air holes are fully open, a non luminous flame is produced. If the air holes are fully closed, a luminous flame is produced. If the air holes are partially open/ closed, a hybrid of non luminous and luminous flames is produced.

Characteristic differences between luminous and non-luminous flame

Luminous flame

Non-luminous flame

1. Produced when the air holes are fully/completely closed.

1. Produced when the air holes are fully/completely open.

2. when the air holes are fully/ completely closed there is incomplete burning/ combustion of the laboratory gas

2.when the air holes are fully/ completely open there is complete burning/ combustion of the laboratory gas

3. Incomplete burning/ combustion of the laboratory gas produces fine unburnt carbon particles which make the flame sooty/smoky

3. Complete burning/ combustion of the laboratory gas does not produce carbon particles. This makes the flame non-sooty /non- smoky.

4. Some carbon particles become white hot and emit light. This flame is thus bright yellow in colour producing light. This makes luminous flame useful for lighting

4. Is mainly blue in colour and is hotter than luminous flame. This makes non-luminous flame useful for heating

5. Is larger, quiet and wavy/easily swayed by wind

5.Is smaller, noisy and steady


 

Luminous flame has three main regions:

(i)the top yellow region where there is incomplete combustion/burning

(ii)the region of unburnt gas below the yellow region where the gas does not burn

(iii) blue region on the sides of region of unburnt gas where there is complete burning

Non-luminous flame has four main regions:

(i)the top colourless region

(ii) Blue region just below where there is complete burning. It is the hottest region

(iii) green region surrounded by the blue region where there is complete burning

(Ii) The region of unburnt gas at the innermost surrounded by green and blue regions. No burning takes place here


 

Scientific apparatus are drawn:

(i) Using a proportional two dimension (2D) cross-sections. Three dimensions (3D) are not recommended.

(ii) Straight edges of the apparatus on a scientific diagram should be drawn using ruler.

(iii) Curved edges of the apparatus on a scientific diagram should be drawn using free hand.

(iv)The bench, tripod or clamp to support apparatus which cannot stand on their own should be shown.




Share this:


subscriber

3 Comments

  • Nankinga Jamirah, September 11, 2023 @ 5:56 am Reply

    The notes are so good and well presented

  • Karim omary, May 28, 2023 @ 8:58 am Reply

    Thank you very much my friend, can you send me the microscope picture

  • Nassoro haruni, April 4, 2023 @ 3:49 am Reply

    I love this app very much it helped me with my study’s

Leave a Reply

Your email address will not be published. Required fields are marked *

Accept Our Privacy Terms.*